Effect of phenylephrine on static and dynamic accommodation

  1. Antonio J. del Águila Carrasco 1
  2. Francisco Lara 2
  3. Paula Bernal-Molina 3
  4. Resurrección Riquelme-Nicolás 2
  5. Iván Marín Franch 4
  6. José J. Esteve Taboada 1
  7. Robert Montés Micó 1
  8. Philip B. Kruger 5
  9. Norberto López Gil 1
  1. 1 Interuniversity laboratory for research in Vision and Optometry. Mixed group UVEG-UMU, Spain
  2. 2 Facultad de Óptica y Optometría, Universidad de Murcia
  3. 3 Department of Optics, and Optometry, and Vision Sciences. University of Valencia. Interuniversity laboratory for research in Vision and Optometry. Mixed group UVEG-UMU, Spain
  4. 4 Department of Optics, and Optometry, and Vision Sciences. University of Valencia; Interuniversity laboratory for research in Vision and Optometry. Mixed group UVEG-UMU,
  5. 5 State College of Optometry. State University of New York, USA
Revista:
Journal of Optometry: peer-reviewed Journal of the Spanish General Council of Optometry

ISSN: 1888-4296

Año de publicación: 2019

Volumen: 12

Número: 1

Páginas: 30-37

Tipo: Artículo

DOI: 10.1016/J.OPTOM.2018.01.005 DIALNET GOOGLE SCHOLAR lock_openAcceso abierto editor

Otras publicaciones en: Journal of Optometry: peer-reviewed Journal of the Spanish General Council of Optometry

Resumen

Objetivo Probamos la hipótesis de que los cambios de la acomodación tras la instilación de Hidrocloruro de Fenilefrina (PHCl) observados en algunos estudios podrían estar originados por los cambios en la óptica. Métodos Realizamos dos experimentos para probar los efectos de PHCl sobre la acomodación estática y dinámica en 8 y 6 sujetos, respectivamente. Se registraron las mediciones objetivas de frente de onda de la respuesta acomodativa estática a un estímulo a diferentes distancias, o la respuesta acomodativa dinámica a un estímulo con movimiento sinusoidal (entre 1 y 3 D de demanda acomodativa a 0,2Hz). Las respuestas se caracterizaron utilizando dos métodos: uno que tiene en cuenta los efectos ópticos midriáticos sobre la acomodación producida por aberraciones de alto orden, y otro que considera únicamente los cambios de potencia paraxialmente, debido a la acción del músculo ciliar, independientemente del tamaño de la pupila. Resultados Al tenerse en cuenta los efectos ópticos midriáticos, las diferencias de las respuestas antes y después de la instilación de PHCl fueron de 0,51±0,53 D, y 0,12±0,15, para la acomodación estática y dinámica, respectivamente, siendo estadísticamente significativas (p<0,039). Al no considerarse los efectos ópticos midriáticos, las diferencias en cuanto a las respuestas antes y después de la instilación de PHCl fueron de −0,2±0,51 D, y −0,05±0,14, para la acomodación estática y dinámica, respectivamente, no siendo estadísticamente significativas (p>0,313). Conclusiones El efecto midriático de PHCl origina cambios ópticos en el ojo que pueden reducir la medición objetiva y subjetiva de la acomodación.

Referencias bibliográficas

  • Eyeson-Annan, M.L.,Hirst, L.W.,Battistutta, D.,Green, A. (1998). Comparative pupil dilation using phenylephrine alone or in combination with tropicamide. Ophthalmology.. 105. 726-732
  • Lovasik, J.V.,Kergoat, H. (1990). Time course of cycloplegia induced by a new phenylephrine-tropicamide combination drug. Optom Vis Sci.. 67. 352-358
  • Charman, W.N.,Whitefoot, H. (1977). Pupil Diameter and the Depth-of-field of the Human Eye as Measured by Laser Speckle. Opt Acta Int J Opt.. 24. 1211-1216
  • Wang, B.,Ciuffreda, K.J. (2006). Depth-of-Focus of the Human Eye: Theory and Clinical Implications. Surv Ophthalmol.. 51. 75-85
  • Campbell, M.C.W.,Harrison, E.M.,Simonet, P. (1990). Psychophysical measurement of the blur on the retina due to optical aberrations of the eye. Vision Res.. 30. 1587-1602
  • Liang, J.,Williams, D.R. (1997). Aberrations and retinal image quality of the normal human eye. JOSA A.. 14. 2873-2883
  • Alpern, M. (1958). Variability of Accommodation during Steady Fixation at Various Levels of Illuminance. JOSA.. 48. 193-197
  • Tucker, J.,Charman, W.N. (1986). Depth of focus and accommodation for sinusoidal gratings as a function of luminance. Am J Optom Physiol Opt.. 63. 58-70
  • Esteve-Taboada, J.J.,Del Águila-Carrasco, A.J.,Bernal-Molina, P.,Ferrer-Blasco, T.,López-Gil, N.,Montés-Micó, R. (2016). Effect of Phenylephrine on the Accommodative System. J Ophthalmol..
  • Biggs, R.D.,Alpern, M.,Bennett, D.R. (1959). The effect of sympathomimetic drugs upon the amplitude of accommodation. Am J Ophthalmol.. 48. 169-172
  • Garner, L.F.,Brown, B.,Baker, R.,Colgan, M. (1983). The effect of phenylephrine hydrochloride on the resting point of accommodation. Invest Ophthalmol Vis Sci.. 24. 393-395
  • Zetterström, C. (1984). The effect of phenylephrine on the accommodative process in man. Acta Ophthalmol.. 62. 872-878
  • Mordi, J.,Tucker, J.,Charman, W.N. (1986). Effects of 0.1% cyclopentolate or 10% phenylephrine on pupil diameter and accommodation. Ophthalmic Physiol Opt.. 6. 221-227
  • Gimpel, G.,Doughty, M.J.,Lyle, W.M. (1994). Large sample study of the effects of phenylephrine 2.5% eyedrops on the amplitude of accommodation in man. Ophthalmic Physiol Opt.. 14. 123-128
  • Sarkar, S.,Hasnat, A.M.,Bharadwaj, S.R. (2012). Revisiting the impact of phenylephrine hydrochloride on static and dynamic accommodation. Indian J Ophthalmol.. 60. 503-509
  • Culhane, H.M.,Winn, B.,Gilmartin, B. (1999). Human dynamic closed-loop accommodation augmented by sympathetic inhibition. Invest Ophthalmol Vis Sci.. 40. 1137-1143
  • Zetterström, C.,Hahnenberger, R. (1988). Pharmacological characterization of human ciliary muscle adrenoceptors in vitro. Exp Eye Res.. 46. 421-430
  • Tram, D.,Kasthurirangan, S.,Ostrin, L.,Glasser, A. (2002). The effects of phenylephrine on accommodation in humans. Optom Vis Sci.. 79. 174
  • Ostrin, L.A.,Glasser, A. (2004). The effects of phenylephrine on pupil diameter and accommodation in rhesus monkeys. Invest Ophthalmol Vis Sci.. 45. 215-221
  • Thibos, L.N.,Hong, X.,Bradley, A.,Applegate, R.A. (2004). Accuracy and precision of objective refraction from wavefront aberrations. J Vis.. 4. 329-351
  • López-Gil, N.,Fernández-Sánchez, V.,Thibos, L.N.,Montés-Micó, R. (2009). Objective Amplitude of Accommodation Computed from Optical Quality Metrics Applied to Wavefront Outcomes. J Optom.. 2. 223-234
  • López-Gil, N.,Fernández-Sánchez, V.,Legras, R.,Montés-Micó, R.,Lara, F.,Nguyen-Khoa, J.L. (2008). Accommodation-related changes in monochromatic aberrations of the human eye as a function of age. Invest Ophthalmol Vis Sci.. 49. 1736-1743
  • Del Águila-Carrasco, A.J.,Marín-Franch, I.,Bernal-Molina, P. (2017). Accommodation Responds to Optical Vergence and Not Defocus Blur Alone. Investig Opthalmology Vis Sci.. 58. 1758-1763
  • Lara, F.,Bernal-Molina, P.,Fernández-Sánchez, V.,López-Gil, N. (2014). Changes in the objective amplitude of accommodation with pupil size. Optom Vis Sci.. 91. 1215-1220
  • Tarrant, J.,Roorda, A.,Wildsoet, C.F. (2010). Determining the accommodative response from wavefront aberrations. J Vis.. 10. 4
  • Petersen, I.,Douglas, I.,Whitaker, H. (2016). Self controlled case series methods: an alternative to standard epidemiological study designs. BMJ. September. 354.
  • Atchison, D.A.,Collins, M.J.,Wildsoet, C.F.,Christensen, J.,Waterworth, M.D. (1995). Measurement of monochromatic ocular aberrations of human eyes as a function of accommodation by the Howland aberroscope technique. Vision Res.. 35. 313-323
  • Young, T. (1801). The Bakerian Lecture: on the mechanism of the eye. Philos Trans R Soc London.. 91. 23-88
  • López-Alcón, D.,Marín-Franch, I.,Fernández-Sánchez, V.,López-Gil, N. (2017). Optical factors influencing the amplitude of accommodation. Vision Res.. 141. 16-22
  • Bernal-Molina, P.,Castejón-Mochón, J.F.,Bradley, A.,López-Gil, N. (2015). Focus correction in an apodized system with spherical aberration. J Opt Soc Am A Opt Image Sci Vis.. 32. 1556-1563
  • Roorda, A.,Bobier, W.R. (1996). Geometrical technique to determine the influence of monochromatic aberrations on retinoscopy. J Opt Soc Am A Opt Image Sci Vis.. 13. 3-11