FACUNDO
BALLESTER PALLARES
CATEDRÁTICO/A DE UNIVERSIDAD
José
Pérez Calatayud
Publications by the researcher in collaboration with José Pérez Calatayud (118)
2024
-
A system for mailed dosimetric audits of 192Ir and 60Co HDR brachytherapy combining OSLD and radiochromic film
Radiation Measurements, Vol. 173
-
Characterization of Plastic Scintillator Detector for In Vivo Dosimetry in Gynecologic Brachytherapy
Journal of Personalized Medicine, Vol. 14, Núm. 3
2023
-
A User-Friendly System for Mailed Dosimetric Audits of 192Ir or 60Co HDR Brachytherapy Sources
Cancers, Vol. 15, Núm. 9
-
Monte Carlo flattening filter design to high energy intraoperative electron beam homogenization
Radiation Physics and Chemistry, Vol. 212
2022
-
A Monte Carlo study of the relative biological effectiveness in surface brachytherapy
Medical Physics, Vol. 49, Núm. 8, pp. 5576-5588
-
Evaluation of dosimetric effects of metallic artifact reduction and tissue assignment on Monte Carlo dose calculations for 125I prostate implants
Medical Physics, Vol. 49, Núm. 9, pp. 6195-6208
-
GEC-ESTRO ACROP recommendations on calibration and traceability of HE HDR-PDR photon-emitting brachytherapy sources at the hospital level
Radiotherapy and Oncology, Vol. 176, pp. 108-117
-
In Vivo Verification of Treatment Source Dwell Times in Brachytherapy of Postoperative Endometrial Carcinoma: A Feasibility Study
Journal of Personalized Medicine, Vol. 12, Núm. 6
2021
-
Source strength determination in iridium-192 and cobalt-60 brachytherapy: A European survey on the level of agreement between clinical measurements and manufacturer certificates
Physics and Imaging in Radiation Oncology, Vol. 19, pp. 108-111
2020
-
Depth-dose measurement corrections for the surface electronic brachytherapy beams of an Esteya® unit: A Monte Carlo study
Physics in Medicine and Biology, Vol. 65, Núm. 24
-
On the use of the absorbed depth-dose measurements in the beam calibration of a surface electronic high-dose-rate brachytherapy unit, a Monte Carlo-based study
Medical Physics, Vol. 47, Núm. 2, pp. 693-702
-
Surface brachytherapy: Joint report of the AAPM and the GEC-ESTRO Task Group No. 253
Medical Physics, Vol. 47, Núm. 10, pp. e951-e987
2019
-
A Monte Carlo-based dosimetric characterization of Esteya ® , an electronic surface brachytherapy unit
Medical Physics, Vol. 46, Núm. 1, pp. 356-369
-
GEC-ESTRO ACROP recommendations on calibration and traceability of LE-LDR photon-emitting brachytherapy sources at the hospital level
Radiotherapy and Oncology, Vol. 135, pp. 120-129
2018
-
Peripheral dose around a mobile linac for intraoperative radiotherapy: Radiation protection aspects
Journal of Radiological Protection, Vol. 38, Núm. 4, pp. 1393-1411
2017
-
Evaluation of the shielding in a treatment room with an electronic brachytherapy unit
Journal of Radiological Protection, Vol. 37, Núm. 2, pp. N5-N12
-
Towards clinical application of RayStretch for heterogeneity corrections in LDR permanent 125I prostate brachytherapy
Brachytherapy, Vol. 16, Núm. 3, pp. 616-623
2016
-
Commissioning and quality assurance procedures for the HDR Valencia skin applicators
Journal of Contemporary Brachytherapy, Vol. 8, Núm. 5, pp. 441-447
-
Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions
Medical Physics, Vol. 43, Núm. 4, pp. 1639-1648
-
Novel simple templates for reproducible positioning of skin applicators in brachytherapy
Journal of Contemporary Brachytherapy, Vol. 8, Núm. 4, pp. 344-348