Dosimetría por imagen en radioembolización hepática con Y90impacto de la resolución espacial del PET

  1. Nuria Carrasco Vela 1
  2. Natalia Tejedor Aguilar 2
  3. Vicente Giménez Gómez 3
  4. Irene Torres Espallardo 2
  1. 1 Hospital Universitario Dr. Peset, Valencia, España
  2. 2 Hospital Universitario y Politécnico La Fe, Valencia, España
  3. 3 Universidad de Valencia - Instituto de Física Corpuscular (IFIC), Valencia, España
Journal:
Revista de Física Médica

ISSN: 1576-6632

Year of publication: 2021

Volume: 22

Issue: 2

Pages: 43-48

Type: Article

DOI: 10.37004/SEFM/2021.22.2.004 DIALNET GOOGLE SCHOLAR lock_openOpen access editor

More publications in: Revista de Física Médica

Abstract

PET image plays a key role in quantitative image-based dosimetry for hepatic Y90 radioembolization. Nevertheless, given the limited scanner spatial resolution, the real activity distribution is blurred. It is usually argued that the blurring introduced by the PET is larger than the one due to the convolution kernel (VSV method) so that Local Deposition Method (LDM) provides suffi-ciently precise results. In the present work we have compared dosimetric results from LDM, VSV and Monte Carlo on synthetic PET images which have been blurred in order to simulate PET spatial resolution.

Bibliographic References

  • Garin E, Tselikas L, Guiu B, et al. Personalised versus standard dosimetry approach of selective internal radiation therapy in patients with locally advanced hepatocellular carcinoma (DOSISPHERE-01): a randomised, multicentre, open-label phase 2 trial. The Lancet Gastroenterology & Hepatology 2021 Jan; 6:17{29. doi: 10.1016/s2468-1253(20)30290-9. Available from: https://doi.org/10.1016/s2468-1253(20)30290-9
  • Ho S, Lau WY, Leung TWT, Chan M, Ngar YK, Johnson PJ, and Li AKC. Partition model for estimating radiation doses from yttrium-90 microspheres in treating hepatic tumours. European Journal of Nuclear Medicine 1996; 23:947{52. doi: 10.1007/bf01084369. Available from: https://doi.org/10.1007/bf01084369
  • Bolch W, Bouchet L, Robertson J, Wessels B, Siegel J, Howell R, Erdi A, Aydogan B, Costes S, Watson E, Brill A, Charkes N, Fisher D, Hays M, and Thomas S. MIRD pamphlet No. 17: the dosimetry of nonuniform activity distributions{radionuclide S values at the voxel level. Medical Internal Radiation Dose Committee. Journal of nuclear medicine : ocial publication, Society of Nuclear Medicine 1999; 40:11S{36S. Available
  • from: http://europepmc.org/abstract/MED/9935083
  • Pasciak AS, Bourgeois AC, and Bradley YC. A Comparison of Techniques for 90Y PET/CT Image-Based Dosimetry Following Radioembolization with Resin Microspheres. Frontiers in Oncology 2014 May; 4. doi: 10.3389/fonc.2014.00121. Available from: https://doi.org/10.3389/fonc.2014. 00121
  • Willowson KP, Tapner M, and Bailey DL. A multicentre comparison of quantitative 90Y PET/CT for dosimetric purposes after radioembolization with resin microspheres. European Journal of Nuclear Medicine and Molecular Imaging 2015 May; 42:1202{22. doi: 10.1007/s00259-015-3059-9. Available from: https://doi.org/10.1007/s00259-015-3059-9
  • Werner MK, Parker JA, Kolodny GM, English JR, and Palmer MR. Respiratory Gating Enhances Imaging of Pulmonary Nodules and measurement of Tracer Uptake in FDG PET/CT. American Journal of Roentgenology 2009 Dec; 193:1640{5. doi: 10.2214/ajr.09.2516. Available from: https://doi. org/10.2214/ajr.09.2516
  • Elmbt L van, Vandenberghe S, Walrand S, Pauwels S, and Jamar F. Comparison of yttrium-90 quantitative imaging by TOF and non-TOF PET in a phantom of liver selective internal radiotherapy. Physics in Medicine and Biology 2011 Oct; 56:6759{77. doi: 10.1088/0031-9155/56/21/001. Available from: https://doi.org/10.1088/0031-9155/56/21/001
  • Bagni O, D'Arienzo M, Chiaramida P, Chiacchiararelli L, Cannas P, D'Agostini A, Cianni R, Salvatori R, and Scopinaro F. 90Y-PET for the assessment of microsphere biodistribution after selective internal radiotherapy. Nuclear Medicine Communications 2012 Feb; 33:198{204. doi: 10.1097/mnm.0b013e32834dfa58. Available from: https://doi.org/10.1097/mnm.0b013e32834dfa58
  • Delso G, Fürst S, Jakoby B, Ladebeck R, Ganter C, Nekolla SG, Schwaiger M, and Ziegler SI. Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner. Journal of Nuclear Medicine 2011 Nov; 52:1914-22. doi: 10.2967/jnumed.111.092726. Available from: https://doi.org/10.2967/jnumed.111.092726